BS6853 Annex D.8.3 Smoke density testing using small scale test method
1. Standard- BS6853 Annex D
BS6853 Annex D: Methods for measuring smoke density
BS6853:1999 Code of practice for fire precautions in the design and construction of passenger carrying trains.
BS 6853 Annex D.8.3 is utilized for Minor Use Materials (Tables 7 and 8 of BS 6853: 1999) and Textiles (Table 11 of BS 6853: 1999).
2. Standard Brief-BS6853 Annex D
The smoke density measurement taken from a material under fire conditions gives an indication of the visibility through the smoke, this is important as reduced visibility in a real fire situation makes it more difficult to escape from a fire hence increasing the threat to human life from the toxic gases, flames and heat.
BS6853 Annex D.8.3—smoke density test using small scale test method
3. BS6853:1999 Standard requirement for Smoke density testing
Interior minor use materials of mass 100g to 500g for BS6853 (BS6853 table 7) requirement: A0 (max)≤0.017.
Exterior minor use materials of mass 400g to 2000g for BS6853 (BS6853 table 7) requirement: A0 (max)≤0.029.
Tel: (+86) 25 86583475 (+86) 400 6036575
Web: www.fire-test.com www.fire-test.cn
Email: info@fire-test.com
Official WeChat-"firetest" or "睿督防火测试"