IMO FTPC Part 2: Smoke and toxicity test
IMO FTPC Part 2: Smoke and toxicity test
IMO FTPC Part 2: Smoke and toxicity test (ISO 5659-2)
IMO FTPC Part 2 Field of application:
Surface materials for bulkheads and ceilings and similar exposed surfaces, floor coverings
Test time is 10 minutes, recording all smoke density and gas content. Samples exposed to 25 or (50) KW/m2 radiation heat conditions, for testing. By CO2, CO, HF, HCI, HCN, NO2, SO2, HBr gas to analyze the toxicity of the eight
IMO FTPC Part 2 Smoke density classification standard:
A test gas than the maximum optical density (Ds) average (Dm)
1. For the bulkhead, lining or ceiling surface, in any experimental conditions, Dm ≤ 200
2. For deck covering material, in any experimental conditions, Dm ≤ 400
3. For the floor surface of the material, in any experimental conditions, Dm ≤ 500
4. For plastic pipes and cables, in any experimental conditions, Dm ≤ 400
IMO FTPC Part 2 Toxicity grading criteria:
CO 1450ppm
HF 600ppm
HCI 600ppm
HCN 140ppm
NO2 350ppm
SO2、 120ppm
HBr 600ppm
IMO Resolution MSC.307(88) – Test list
FTPC Part 1: Non-combustibility test
FTPC Part 2: Smoke and toxicity test
FTPC Part 3: Test for “A”, “B” and “F” class divisions
FTPC Part 4: Test for fire door control systems
FTPC Part 5: Test for surface flammability (Test for surface materials and primary deck Coverings)
FTPC Part 7: Test for vertically supported textiles and films
FTPC Part 8: Test for upholstered furniture
FTPC Part 9: Test for bedding components
FTPC Part 10: Test for fire-restricting materials for high-speed craft
FTPC Part 11: Test for fire-resisting division of high-speed craft
Tel: (+86) 25 86583475 (+86) 400 6036575
Web: www.fire-test.com www.fire-test.cn
Email: info@fire-test.com